Note: one long   aerator is used for 25T/H or under  100T/H,two   aerators are used for 100-175T/H,and three aerators are used for   200-320T/H,and so on. One short aerator is used for 20T/H or under 20T/H. Or according to the pool depth to   choose: The pool depth 1.8 meters below the selection of short aeration   machine, pool depth 1.8 meters above the selection of long aeration machine

  3、Notes

1) The cavitation aerator must be run in the forward direction (clockwise, according to the direction of the red arrow).The cavitation aerator is prohibited to run if there is no water in the pool.

2) 2)You should always pay attention to the noise in operation, if there is noise, should immediately stop the machine, and  check the motor , the aerator couplings and the glue zygotes whether they are damaged, if they are damaged must be replaced in time.

3) if there is any noise after the replacement of the adhesive, it should be checked whether the bearing or mechanical seal is damaged or flooded, and immediately shut down for maintenance or contact with the manufacturer.

4) if no aeration, first check the aeration machine whether it is reverse, the motor can be turned into a positive. Then check the impeller outlet whether is blocked, if congestion, need to clean up aeration impeller.